You can address this situation in 2 ways:
â–  Turn off this design rule in the cleanup group definition. For more
information, see Creating a Wall Cleanup Group Definition on page 1338.
â–  Temporarily assign the walls to the same cleanup group, copy or move the
objects, and then reassign the walls to their correct cleanup groups.
Opening a Drawing that Displays New Solution Tip Icons
When I closed my drawing, all the wall cleanups looked fine. Now when I
open the drawing, there are solution tip icons in the drawing. What causes
this, and how can I fix it?
Under some circumstances, the order in which walls are cleaned up affects
the display.
When troubleshooting this condition, select the walls in question, and
double-click one of them. On the Properties palette, select No for Cleanup
automatically, and then select Yes. Try this on different walls to see whether
you can locate the unstable wall. Usually, adjusting the justification line of
the unstable wall fixes this problem. For more information about verifying
justification line, see Wall Justification Lines and Cleanup Circles on page 1319.
Working with Wall Cleanups and Xref Drawings
How can I get walls to clean up with walls in xref drawings?
There are several actions you can take to improve wall cleanup when you work
with xref drawings that contain walls:
â–  Verify the design rules of the cleanup groups used in the xref drawings. If
the cleanup group in the xref drawing does not allow cleanup with the
walls in the host drawing, walls in the 2 drawings do not clean up, even
when their cleanup groups have the same name. For more information
about the design rules of cleanup groups, see Creating a Wall Cleanup
Group Definition on page 1338.
â–  When adding new walls during a Refedit session, add the existing walls to
the current working set. Select the Xref cleanup group of the existing walls
for the walls you are adding. Otherwise, the new walls do not clean up
with the existing walls until you save changes to the drawings.
â–  Use the Regenall (Regenerate All) and ObjRelUpdate (Object Relationship
Update) commands to update the relationships among walls in the drawing,
Troubleshooting Wall Cleanups | 1335