Remote control commands
R&S
®
MXO 5 Series
702User Manual 1802.3369.02 ─ 02
SBUS<sb>:CAN:SAMPlepoint <SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<SamplePoint> Range: 30 to 90
Increment: 5
*RST: 66
Default unit: %
Usage: Asynchronous command
Manual operation: See "Sample point" on page 342
SBUS<sb>:CAN:SOURce
Source
Sets the source channel to which the line is connected.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
Source C1 | C2 | C3 | C4 | C5 | C6 | C7 | C8 | D0 | D1 | D2 | D3 | D4 | D5
| D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 | D15 | M1 | M2
| M3 | M4 | M5 | M6 | M7 | M8 | R1 | R2 | R3 | R4 | R5 | R6 | R7 |
R8
Usage: Asynchronous command
Manual operation: See "Data" on page 341
SBUS<sb>:CAN:FDATa:DBITrate <FDBitrate>
Sets the bit rate of the data phase.
Suffix:
<sb>
.
1...4, index of the serial bus
Parameters:
<FDBitrate> Range: 10000 to 15000000
Increment: 100
*RST: 1000000
Default unit: bps
Usage: Asynchronous command
Manual operation: See "FD bit rate" on page 342
SBUS<sb>:CAN:FDATa:SAMPlepoint <FDSamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.