Trigger
R&S
®
MXO 5 Series
156User Manual 1802.3369.02 ─ 02
Absolute hysteresis
Defines a range in absolute values around the trigger level. If the signal oscillates
inside this range and thus crosses the trigger level, no trigger event occurs.
Remote command:
TRIGger:NOISe<m>:ABSolute on page 513
Relative hysteresis
Defines a range in divisions around the trigger level in division or as percentage. If the
signal oscillates inside this range and thus crosses the trigger level, no trigger event
occurs.
Remote command:
TRIGger:NOISe<m>:PERDivision on page 514
TRIGger:NOISe<m>:RELative on page 515
7.6 Channel filter
Access: "Menu">"Trigger" > "Channel filter"
Trigger filter mode
Selects the filter mode for the trigger channel.
"Off"
The trigger signal is not filtered.
"LF reject"
Frequencies lower than the "LF reject BW" are rejected, higher fre-
quencies pass the filter.
"RF reject"
Frequencies higher than the "RF reject BW" are rejected, lower fre-
quencies pass the filter.
Remote command:
TRIGger:FILTermode on page 515