Remote control commands
R&S
®
MXO 5 Series
570User Manual 1802.3369.02 ─ 02
Manual operation: See "Mode" on page 198
GATE<g>:ABSolute:STARt <Start>
GATE<g>:ABSolute:STOP <Stop>
Define the absolute start and end values for the gate, respectively.
Available, if GATE<g>:GCOupling = MANUal and GATE<g>:MODE =ABS.
Suffix:
<g>
.
1...8, index of the gate
Parameters:
<Stop> Range: -1E+26 to 1E+26
Increment: 0.01
*RST: 0.01
Usage: Asynchronous command
Manual operation: See "Mode" on page 198
GATE<g>:RELative:STARt <RelativeStart>
GATE<g>:RELative:STOP <RelativeStop>
Define the relative start and end values for the gate, respectively.
Available, if GATE<g>:GCOupling = MANUal and GATE<g>:MODE =REL.
Suffix:
<g>
.
1...8, index of the gate
Parameters:
<RelativeStop> Range: 0 to 100
Increment: 0.1
*RST: 100
Default unit: %
Usage: Asynchronous command
Manual operation: See "Mode" on page 198
GATE<g>:SHOW <DisplayState>
If enabled, the gate area is indicated in the source diagram.
Suffix:
<g>
.
1...8, index of the gate
Parameters:
<DisplayState> ON | OFF
*RST: ON
Usage: Asynchronous command