Remote control commands
R&S
®
MXO 5 Series
501User Manual 1802.3369.02 ─ 02
Suffix:
<ev>
.
1, can be omitted
Parameters:
<Polarity> POSitive | NEGative | EITHer
*RST: POSitive
Usage: Asynchronous command
Manual operation: See "Polarity" on page 141
TRIGger:EVENt<ev>:RUNT:RANGe
<Mode>
Defines the time limit of the runt pulse in relation to the TRIGger:EVENt<ev>:RUNT:
WIDTh and TRIGger:EVENt<ev>:RUNT:DELTa settings.
Suffix:
<ev>
.
1, can be omitted
Parameters:
<Mode> ANY | LONGer | SHORter | WITHin | OUTSide
ANY
Triggers on all runts fulfilling the level condition, without time lim-
itation.
LONGer
Triggers on runts longer than the given runt width.
SHORter
Triggers on runts shorter than the given runt width.
WITHin
Triggers if the runt length is inside a given time range. The range
is defined by runt width and ±Delta.
OUTSide
Triggers if the runt length is outside a given time range. The
range is defined by runt width and ±Delta.
*RST:
ANY
Usage: Asynchronous command
Manual operation: See "Range" on page 145
TRIGger:EVENt<ev>:RUNT:WIDTh <Width>
Defines the upper or lower voltage threshold.
It is not available if TRIGger:EVENt<ev>:RUNT:RANGe is set to ANY.
Suffix:
<ev>
.
1, can be omitted
Trigger