Remote control commands
R&S
®
MXO 5 Series
476User Manual 1802.3369.02 ─ 02
17.8.7 Fast segmentation
ACQuire:SEGMented:STATe <State>
If fast segmentation is enabled, the acquisitions are performed as fast as possible,
without processing and displaying the waveforms. When acquisition has been stopped,
the data is processed and the latest waveform is displayed. Older waveforms are
stored in segments. You can display and analyze the segments using the history.
Parameters:
<State> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Fast segmentation" on page 111
ACQuire:SEGMented:MAX
<MaxAcqs>
If ON, the instrument acquires the maximum number of segments that can be stored in
the memory. The maximum number depends on the current sample rate and record
length settings.
If OFF, define the number of segments in a fast segmentation cycle with ACQuire:
COUNt.
Parameters:
<MaxAcqs> ON | OFF
*RST: OFF
Usage: Asynchronous command
Manual operation: See "Acquire maximum" on page 110
17.8.8 Probes
Common probe settings........................................................................................476
Settings for active voltage probes.........................................................................481
Settings for current probes....................................................................................487
Probe attributes.....................................................................................................489
17.8.8.1 Common probe settings
The probe suffix <ch> selects the input channel to which the probe is connected.
PROBe<ch>:SETup:ATTenuation[:AUTO]?....................................................................... 477
PROBe<ch>:SETup:ATTenuation:MANual........................................................................ 477
PROBe<ch>:SETup:ATTenuation:DEFProbe.....................................................................477
PROBe<ch>:SETup:ATTenuation:UNIT............................................................................ 478
PROBe<ch>:SETup:BANDwidth?.................................................................................... 478
PROBe<ch>:SETup:OFFSet:TOMean..............................................................................479