Remote control commands
R&S
®
MXO 4 Series
701User Manual 1335.5337.02 ─ 05
WGENerator<wg>:FUNCtion:RAMP[:SYMMetry]...............................................................702
WGENerator<wg>:FUNCtion[:SELect]..............................................................................702
WGENerator<wg>:FUNCtion[:SQUare]:DCYCle................................................................702
WGENerator<wg>:OUTPut[:LOAD]..................................................................................703
WGENerator<wg>:PERiod..............................................................................................703
WGENerator<wg>:PRESet............................................................................................. 703
WGENerator<wg>:VOLTage:DCLevel.............................................................................. 704
WGENerator<wg>:VOLTage:HIGH...................................................................................704
WGENerator<wg>:VOLTage:INVersion.............................................................................704
WGENerator<wg>:VOLTage:LOW................................................................................... 704
WGENerator<wg>:VOLTage:OFFSet............................................................................... 705
WGENerator<wg>:VOLTage[:VPP].................................................................................. 705
WGENerator<wg>[:ENABle]............................................................................................705
WGENerator<wg>:ACOPy
Copies all settings from Gen1/Gen2 and applies them to Gen2/Gen1.
Suffix:
<wg>
.
1..2
Usage: Setting only
Asynchronous command
WGENerator<wg>:FREQuency <Frequency>
Sets the frequency of the waveform.
Suffix:
<wg>
.
1..2
Parameters:
<Frequency> Range: 0.001 to 100000000
Increment: 1
*RST: 10000000
Default unit: Hz
Usage: Asynchronous command
Manual operation: See "Frequency" on page 362
WGENerator<wg>:FUNCtion:PULSe[:WIDTh] <PulseWidth>
Sets the pulse width, the pulse duration of the generated pulse waveform.
Suffix:
<wg>
.
1..2
Parameters:
<PulseWidth> Range: 1.65E-08 to 90000
Increment: 1
*RST: 5E-07
Default unit: s
Waveform generator (option R&S MXO4-B6)