Panasonic AJ-CX4000GJ Pro 4K/HDR Streaming Camcorder with B4 Lens Mount

User Manual - Page 109

For AJ-CX4000GJ.

PDF File Manual, 245 pages, Read Online | Download pdf file

AJ-CX4000GJ photo
Loading ...
Loading ...
Loading ...
109 –
Chapter 4 Operation — Menu settings
[BATTERY] Select when connecting the battery.
Voltage to display full/near end/end remaining capacity can be set in the [OTHERS] menu [BATTERY] [DC IN
BATTERY].
(Factory setting: [DC POWER SUPPLY])
[DC IN BATTERY]
[FULL VOLT] Sets the voltage to display full remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [13.0V] … [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
[NEAR END VOLT] Sets the voltage to display near end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.1V] … [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
[END VOLT] Sets the voltage to display end remaining capacity when inputting an external battery from the <DC IN> terminal.
The items that can be set are as follows.
f [11.0V] … [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
[ONBOARD BATTERY]
[BATTERY SEL] Select according to the used battery.
When set to [DIONIC], [HYTRON/TITON], [ENDURA], or [PAG], remaining capacity is detected and the warning is displayed
according to the [NEAR END INFO] or the [END INFO] setting.
The remaining capacity is detected by the voltage level when set to [other].
When there is no remaining capacity information, the remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [DIONIC], [HYTRON/TITON], [ENDURA], [PAG], [other]
(Factory setting: [DIONIC])
[FULL VOLT] Sets the voltage to display full remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [13.0V] … [17.0V] (0.1 V steps)
(Factory setting: [15.5V])
[NEAR END VOLT] Sets the voltage to display near end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [11.1V] … [15.0V] (0.1 V steps)
(Factory setting: [13.2V])
[END VOLT] Sets the voltage to display end remaining capacity when the battery remaining capacity is detected by the voltage level.
The items that can be set are as follows.
f [11.0V] … [14.9V] (0.1 V steps)
(Factory setting: [12.5V])
[NEAR END INFO] Sets the percent value of the near end remaining capacity when the remaining capacity information is acquired from the
battery.
The items that can be set are as follows.
f [4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
(Factory setting: [5%])
[END INFO] Sets the percent value of the end remaining capacity when the remaining capacity information is acquired from the battery.
The items that can be set are as follows.
f [1%] … [10%] (1% steps)
(Factory setting: [1%])
[GENLOCK]
[GENLOCK]
Switches the synchronization signal of the camera.
[INT] Synchronizes to the internal standard signal regardless of the standard signal input to the <GENLOCK IN> terminal.
[GL IN] Synchronizes to the standard signal input to the <GENLOCK IN> terminal.
(Factory setting: [INT])
[H PHASE COARSE]
Performs coarse adjustment to match horizontal synchronization phase when building a system.
The items that can be set are as follows.
f [100]…[100]
(Factory setting: [0])
[H PHASE FINE]
Performs ne adjustment to match horizontal synchronization phase when building a system.
The items that can be set are as follows.
f [100]…[100]
(Factory setting: [0])
Loading ...
Loading ...
Loading ...