SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
445
3 Function diagrams
3.17 Diagnostics
Fig. 3-108 8065 – Alarm buffer
- 8065 -
Function diagram
87654321
fp_8065_97_05.vsd
Diagnostics
SINAMICS G120C
07.04.2014 V4.7
Alarm buffer
RESET
1
III
RESET
[2546.7]
p2112
r2122[0]
r2122[1]
r2122[7]
r2124[0] [I32]
r2134[0] [Float]
r2124[1] [I32]
r2134[1] [Float]
r2124[7] [I32]
r2134[7] [Float]
r2123[0] [ms]
r2123[1] [ms]
r2123[7] [ms]
r2125[0] [ms]
r2125[1] [ms]
r2125[7] [ms]
[8060.1]
POWER ON
r2122[8]
r2122[9]
r2122[63]
r2124[8] [I32]
r2134[8] [Float]
r2124[9] [I32]
r2134[9] [Float]
r2124[63] [I32]
r2134[63] [Float]
r2123[8] [ms]
r2123[9] [ms]
r2123[63] [ms]
r2125[8] [ms]
r2125[9] [ms]
r2125[63] [ms]
<1>
<1>
Operating time
The buffer parameters are updated cyclically in the background (see status signal in r2139).
Alarm times
Alarm 1
(oldest)
Alarm 2
Alarm 8
(most
recent)
Alarm history
Alarm 1
(most
recent)
Alarm 2
Alarm 56
(oldest)
Alarm code Alarm value
Alarm time
"received"
Alarm time
"removed"
Alarms
counter
p2111
p2111 = 0:
Alarm buffer is deleted
Alarm appears
Delete alarm buffer
Counter
16 bit
r2138
r2138
.10
Alarm number
r2110
0 = "No alarm present"
r2132
Actual alarm code
3121[0]
3121[1]
3121[7]
3121[8]
3121[9]
3121[63]
r3123[0]
r3123[1]
r3123[7]
r3123[8]
r3123[9]
r3123[63]
Component
alarm
r2122 = 0
r2123 = 0
r2124 = 0
r2125 = 0
r2134 = 0
r3121 = 0
r3123 = 0
Diagnostic
attribute
alarm
1 = External alarm 1
(A07850)
III
RESET
POWER ON
Fault buffer change
[8060.8]
Alarm
appears
Alarm
disappears
Delete alarm
buffer
16 bit counter,
free running
r2120
Sum buffer changed
1 = Alarm present
ZSW fault/alarm 1
r2139
r2139
.7
[2548.2]
1
1 = Alarm class bit 0
1 = Alarm class bit 1
1 = Maintenance required
1 = Maintenance urgently required
r2139.11
r2139.12
r2139.13
r2139.14