User Manual - Page 391

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
391
3 Function diagrams
3.10 Safety Integrated Basic Functions
Fig. 3-61 2812 – F-DI: Fail-safe Digital Input
- 2812 -
Function diagram
87654321
fp_2812_97_66.vsd
Safety Integrated Basic Functions
SINAMICS G120C
07.04.2014 V4.7
F-DI (Fail-safe Digital Input)
&
F-DI 0
=1
SI STO t_debou P1
0.00 ... 100.00 [ms]
p9651 (1.00)
SI STO t_debou P2
0.00 ... 100000.00 [µs]
p9851 (0.00)
T0
SI F-DI chg t P1
0.00 ... 2000.00 [ms]
p9650 (500.00)
SI F-DI chg t P2
0.00 ... 2000000.00 [µs]
p9850 (500000.00)
Kl. 9
Kl. 16
Kl. 69
Kl. 17
Kl. 34
Kl. 28
GND
+24V OUT
DI 4
DI COM
DI 5
DI COM2
[2810.6]