User Manual - Page 203

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
203
2 Parameters
2.2 List of parameters
Description: Displays the code of the last alarm that occurred.
Note: 0: No alarm present.
Description: Displays additional information about the fault that occurred for float values.
Dependency: Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2136
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description: Displays additional information about the active alarm for float values.
Dependency: Refer to: r2110, r2122, r2123, r2124, r2125, r3121, r3123
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
Description: Display and BICO output for the second status word of faults and alarms.
Description: Displays the system runtime in days when the fault was removed.
Dependency: Refer to: r0945, r0947, r0948, r0949, r2109, r2130, r2133
Notice: The time comprises r2136 (days) and r2109 (milliseconds).
Note: The buffer parameters are cyclically updated in the background (refer to status signal in r2139).
r2132 CO: Actual alarm code / Actual alarm code
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 8065
Min Max Factory setting
- - -
r2133[0...63] Fault value for float values / Fault val float
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 8060
Min Max Factory setting
- - -
r2134[0...63] Alarm value for float values / Alarm value float
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 8065
Min Max Factory setting
- - -
r2135.12...15 CO/BO: Status word faults/alarms 2 / ZSW fault/alarm 2
Access level: 2 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 2548
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
12 Fault motor overtemperature Yes No 8016
13 Fault power unit thermal overload Yes No 8014
14 Alarm motor overtemperature Yes No 8016
15 Alarm power unit thermal overload Yes No 8014
r2136[0...63] Fault time removed in days / t_flt resolv days
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 8060
Min Max Factory setting
- - -
Loading ...
Loading ...
Loading ...