User Manual - Page 281

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
281
2 Parameters
2.2 List of parameters
Description: Displays the controller assignment of a PROFINET subslot on the actual drive object.
Index: [0] = Subslot 2 PROFIsafe
[1] = Subslot 3 PZD telegram
[2] = Subslot 4 PZD supplementary data
Dependency: Refer to: r8961, r8962
Note: Example:
If the parameter contains the value 2 in index [1], then this means that subslot 3 is assigned to controller 2.
Description: Displays the IP address of the first PROFINET controller connected with the device via PN onboard.
Description: Displays the IP address of the second PROFINET controller connected with the device via PN onboard.
Description: Sets the profile for Ethernet/IP.
Value: 0: SINAMICS
1: ODVA AC/DC
Note: Changes only become effective after POWER ON.
The parameter is not influenced by setting the factory setting.
ODVA: Open DeviceNet Vendor Association
Description: Sets the STOP mode for the Ethernet/IP ODVA profile (p8980 = 1).
Value: 0: OFF1
1: OFF2
Dependency: Refer to: p8980
r8960[0...2] PN subslot controller assignment / PN subslot assign
G120C_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 8 -
r8961[0...3] PN IP Address Remote Controller 1 / IP Addr Rem Ctrl1
G120C_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 255 -
r8962[0...3] PN IP Address Remote Controller 2 / IP Addr Rem Ctrl2
G120C_PN Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 255 -
p8980 Ethernet/IPprofile / Eth/IP profile
G120C_PN Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p8981 Ethernet/IP ODVA STOP mode / Eth/IP ODVA STOP
G120C_PN Access level: 3 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0