User Manual - Page 375

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
375
3 Function diagrams
3.8 Internal control/status words
Fig. 3-47 2526 – Status word, closed-loop control
- 2526 -
Function diagram
87654321
fp_2526_97_66.vsd
Internal control/status words
SINAMICS G120C
07.04.2014 V4.7
Status word, closed-loop control (r0056)
1
2
4
0
7
8
9
11
14
15
[6722.6]
[6722.3]
[6714.8]
3
5
6
12
13
10[6310.8]
<1>
<1>
<1>
<1>
<1>
[6060.8]
[6710.1]
[8012.5]
Only for U/f control.
Status word closed-loop control (r0056)Bit No.
1 = Initialization completed
1 = De-magnetization completed
1 = Pulse enable available
1 = Soft starting available
1 = Magnetization completed
1 = Acceleration voltage active
1 = Frequency, negative
1 = Field weakening active
1 = Voltage limit active
1 = Slip limiting active
1 = Frequency limit active
1 = Current limiting controller, voltage output active
1 = Current/torque limiting active
1 = Vdc_max controller active
1 = Vdc_min controller active
ZSW cl-loop ctrl
r0056
r0056
1 = Starting boost active
r0056.0
r0056.1
r0056.4
r0056.5
r0056.11
r0056.12
r0056.2
r0056.6
r0056.9
r0056.13
r0056.14
r0056.15
r0056.3
r0056.7
r0056.8
r0056.10
<1>
[6030.6], [6710.1]
[6730.4], [6731.4]
[6730.4], [6731.4]
[2510.1], [8012.5]
[2701.1]
[6301.2]
[6301.4]
[6710.5]
[6220.8], [6320.8]
[6220.8], [6320.8]