User Manual - Page 307

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
307
2 Parameters
2.4 BICO parameters (connectors/binectors)
p3331[0...n] BI: 2/3 wire control command 2 / 2/3 wire cmd 2
p3332[0...n] BI: 2/3 wire control command 3 / 2/3 wire cmd 3
p5614 BI: Pe set switch-on inhibit signal source / Pe sw on_inh s_src
p8785 BI: CAN status word bit 8 / Status word bit 8
p8786 BI: CAN status word bit 14 / Status word bit 14
p8787 BI: CAN status word bit 15 / Status word bit 15
2.4.2 Connector inputs (CI)
Product: SINAMICS G120C, Version: 4702900, Language: eng, Type: CI
p0771[0...1] CI: CU analog outputs signal source / CU AO S_src
p1044[0...n] CI: Motorized potentiometer setting value / Mop set val
p1070[0...n] CI: Main setpoint / Main setpoint
p1071[0...n] CI: Main setpoint scaling / Main setp scal
p1075[0...n] CI: Supplementary setpoint / Suppl setp
p1076[0...n] CI: Supplementary setpoint scaling / Suppl setp scal
p1106[0...n] CI: Minimum speed signal source / n_min s_src
p1138[0...n] CI: Ramp-function generator ramp-up time scaling / RFG t_RU scal
p1139[0...n] CI: Ramp-function generator ramp-down time scaling / RFG t_RD scal
p1330[0...n] CI: U/f control independent voltage setpoint / Uf U_set independ.
p1352[0...n] CI: Motor holding brake starting frequency signal source / Brake f_start
p1475[0...n] CI: Speed controller torque setting value for motor holding brake / n_ctrl M_sv MHB
p1511[0...n] CI: Supplementary torque 1 / M_suppl 1
p1522[0...n] CI: Torque limit upper / M_max upper
p1523[0...n] CI: Torque limit lower / M_max lower
p1552[0...n] CI: Torque limit upper scaling without offset / M_max up w/o offs
p1554[0...n] CI: Torque limit lower scaling without offset / M_max low w/o offs
p2016[0...3] CI: Comm IF USS PZD send word / Comm USS send word
p2051[0...13] CI: PROFIdrive PZD send word / PZD send word
p2061[0...12] CI: PROFIBUS PZD send double word / PZD send DW
p2099[0...1] CI: Connector-binector converter signal source / Con/bin S_src
p2253[0...n] CI: Technology controller setpoint 1 / Tec_ctrl setp 1
p2254[0...n] CI: Technology controller setpoint 2 / Tec_ctrl setp 2
p2264[0...n] CI: Technology controller actual value / Tec_ctrl act val
p2289[0...n] CI: Technology controller pre-control signal / Tec_ctr prectr_sig
p2296[0...n] CI: Technology controller output scaling / Tec_ctrl outp scal
p2297[0...n] CI: Technology controller maximum limit signal source / Tec_ctrMaxLimS_src
p2298[0...n] CI: Technology controller minimum limit signal source / Tec_ctrl min_l s_s
p2299[0...n] CI: Technology controller limit offset / Tech_ctrl lim offs
p8746[0...15] CI: CAN free PZD send objects 16 bit / Free PZD send 16
p8748[0...7] CI: CAN free PZD send objects 32 bit / Free PZD send 32
2.4.3 Binector outputs (BO)
Product: SINAMICS G120C, Version: 4702900, Language: eng, Type: BO
r0751.0...9 BO: CU analog inputs status word / CU AI status word
r0785.0...1 BO: CU analog outputs status word / CU AO ZSW
r0807.0 BO: Master control active / PcCtrl active
r1025.0 BO: Fixed speed setpoint status / n_setp_fix status
r2043.0...2 BO: PROFIdrive PZD state / PD PZD state
r2090.0...15 BO: PROFIdrive PZD1 receive bit-serial / PZD1 recv bitw
r2091.0...15 BO: PROFIdrive PZD2 receive bit-serial / PZD2 recv bitw
Loading ...
Loading ...
Loading ...