2.4 BICO parameters (connectors/binectors)
p1012[0...n] CO: Fixed speed setpoint 12 / n_set_fixed 12
p1013[0...n] CO: Fixed speed setpoint 13 / n_set_fixed 13
p1014[0...n] CO: Fixed speed setpoint 14 / n_set_fixed 14
p1015[0...n] CO: Fixed speed setpoint 15 / n_set_fixed 15
r1024 CO: Fixed speed setpoint effective / n_set_fixed eff
r1045 CO: Mot. potentiometer speed setp. in front of ramp-fct. gen. / Mop n_set bef RFG
r1050 CO: Motor. potentiometer setpoint after the ramp-function generator / Mop setp after RFG
r1073 CO: Main setpoint effective / Main setpoint eff
r1077 CO: Supplementary setpoint effective / Suppl setpoint eff
r1078 CO: Total setpoint effective / Total setpoint eff
p1083[0...n] CO: Speed limit in positive direction of rotation / n_limit pos
r1084 CO: Speed limit positive effective / n_limit pos eff
p1086[0...n] CO: Speed limit in negative direction of rotation / n_limit neg
r1087 CO: Speed limit negative effective / n_limit neg eff
r1112 CO: Speed setpoint after minimum limiting / n_set aft min_lim
r1114 CO: Setpoint after the direction limiting / Setp after limit
r1119 CO: Ramp-function generator setpoint at the input / RFG setp at inp
r1149 CO: Ramp-function generator acceleration / RFG acceleration
r1150 CO: Ramp-function generator speed setpoint at the output / RFG n_set at outp
r1170 CO: Speed controller setpoint sum / n_ctrl setp sum
r1258 CO: Vdc controller output / Vdc_ctrl output
r1298 CO: Vdc controller output (U/f) / Vdc_ctrl output
r1337 CO: Actual slip compensation / Slip comp act val
r1343 CO: I_max controller frequency output / I_max_ctrl f_outp
r1348 CO: U/f control Eco factor actual value / U/f Eco fac act v
p1351[0...n] CO: Motor holding brake starting frequency / Brake f_start
r1438 CO: Speed controller speed setpoint / n_ctrl n_set
r1445 CO: Actual speed smoothed / n_act smooth
r1482 CO: Speed controller I torque output / n_ctrl I-M_outp
r1493 CO: Moment of inertia total, scaled / M_mom inert tot_sc
r1508 CO: Torque setpoint before supplementary torque / M_set bef. M_suppl
r1516 CO: Supplementary torque and acceleration torque / M_suppl + M_accel
p1520[0...n] CO: Torque limit upper / M_max upper
p1521[0...n] CO: Torque limit lower / M_max lower
p1524[0...n] CO: Torque limit upper scaling / M_max upper scal
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
r1526 CO: Torque limit upper without offset / M_max up w/o offs
r1527 CO: Torque limit lower without offset / M_max low w/o offs
r1538 CO: Upper effective torque limit / M_max upper eff
r1539 CO: Lower effective torque limit / M_max lower eff
r1547[0...1] CO: Torque limit for speed controller output / M_max outp n_ctrl
p1563[0...n] CO: Mom. of inertia estimator load torque direction of rotation pos. / J_est M pos
p1564[0...n] CO: Mom. of inertia estimator load torque direction of rotation neg. / J_est M neg
p1570[0...n] CO: Flux setpoint / Flex setp
r1598 CO: Total flux setpoint / Flux setp total
r1732[0...1] CO: Direct-axis voltage setpoint / Direct U set
r1733[0...1] CO: Quadrature-axis voltage setpoint / Quad U set
r1801[0...1] CO: Pulse frequency / Pulse frequency
r2050[0...11] CO: PROFIBUS PZD receive word / PZD recv word
r2060[0...10] CO: PROFIdrive PZD receive double word / PZD recv DW
r2089[0...4] CO: Send binector-connector converter status word / Bin/con ZSW send
r2120 CO: Sum of fault and alarm buffer changes / Sum buffer changed
r2131 CO: Actual fault code / Act fault code
r2132 CO: Actual alarm code / Actual alarm code
r2169 CO: Actual speed smoothed signals / n_act smth message