3 Function diagrams
3.8 Internal control/status words
Fig. 3-45 2513 – Control word 2 (r0055)
- 2513 -
Function diagram
87654321
fp_2513_97_05.vsd
Internal control/status words
SINAMICS G120C
07.04.2014 V4.7
Control word 2 (r0055)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0
Bit No. Control word 2 (r0055)
1 = Fixed setp bit 0
1 = Fixed setp bit 1
1 = Fixed setp bit 2
1 = Fixed setp bit 3
Reserved
Reserved
1 = Technology controller enable
1 = DC brake enable
Reserved
Reserved
Reserved
0 = External fault 1 (F07860)
Reserved
1 = CDS bit 1
Suppl STW
r0055
r0055
Sequence control
DC braking control
Technology controller
Fixed frequencies
Fixed frequencies
Fixed frequencies
Fixed frequencies
STW setpoint chan
r1198
r1198
.0
[2505.7]
STW setpoint chan
r1198
r1198
.1
[2505.7]
STW setpoint chan
r1198
r1198
.2
[2505.7]
STW setpoint chan
r1198
r1198
.3
[2505.7]
Tec_ctrl status
r2349
r2349
.0
[7958.6]
DCBRK ZSW
r1239
r1239
.11
[7017.7]
STW fault/alarm
r2138
r2138
.13
[2546.7]
Reserved
1 = DDS select. bit 0
CDS selected
r0836
r0836
.1 Sequence control
[8560.7]
DDS selected
r0837
r0837
.0
[8565.6]
Sequence control