2 Parameters
2.2 List of parameters
Description: Configuration of voltage generation for the various MotID sections in the case of the most recent successful MotID.
Description: For service personnel only.
Description: Setting to acknowledge all active faults of a drive object.
Notice: Safety messages cannot be acknowledged using this parameter.
Note: Parameter should be set from 0 to 1 to acknowledge.
After acknowledgement, the parameter is automatically reset to 0.
r3929[0...n] Motor data identification modulated voltage generation / MotID U_gen mod
Access level: 4 Calculated: p0340 = 1 Data type: Unsigned32
Can be changed: - Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
Bit field: Bit Signal name 1 signal 0 signal FP
00 Wobble U_generate to determine dead-time
correction
Yes No -
01 Wobble U_generate to determine stator
resistance
Yes No -
02 Wobble U_generation to determine rotor
time constant
Yes No -
03 Wobble U_generation to determine leakage
inductance
Yes No -
04 Wobble U_generation to determine dynamic
leakage inductance
Yes No -
05 Wobble U_generation to determine
magnetizing inductance
Yes No -
08 Alternating U_generate to determine dead-
time correction
Yes No -
09 Alternating U_generate to determine stator
resistance
Yes No -
10 Alternating U_generate to determine rotor
time constant
Yes No -
11 Alternating U_generate to determine
leakage inductance
Yes No -
12 Alternating U_generate to determine dyn.
leakage inductance
Yes No -
13 Alternating U_generate to determine
magnetizing inductance
Yes No -
p3950 Service parameter / Serv par
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: C, U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - -
p3981 Faults acknowledge drive object / Faults ackn DO
Access level: 3 Calculated: - Data type: Unsigned8
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: 8060
Min Max Factory setting
0 1 0