User Manual - Page 211

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
211
2 Parameters
2.2 List of parameters
Description: Sets the value for fixed value 13 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description: Sets the value for fixed value 14 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description: Sets the value for fixed value 15 of the technology controller.
Dependency: Refer to: p2220, p2221, p2222, p2223, r2224, r2229
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Description: Sets the method to select the fixed setpoints.
Value: 1: Direct selection
2: Binary selection
Description: Sets the signal source to select a fixed value of the technology controller.
Dependency: Refer to: p2221, p2222, p2223
p2213[0...n] CO: Technology controller fixed value 13 / Tec_ctr fix val 13
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: PERCENT Dyn. index: DDS, p0180
Units group: 9_1 Unit selection: p0595 Func. diagram: 7950
Min Max Factory setting
-200.00 [%] 200.00 [%] 130.00 [%]
p2214[0...n] CO: Technology controller fixed value 14 / Tec_ctr fix val 14
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: PERCENT Dyn. index: DDS, p0180
Units group: 9_1 Unit selection: p0595 Func. diagram: 7950
Min Max Factory setting
-200.00 [%] 200.00 [%] 140.00 [%]
p2215[0...n] CO: Technology controller fixed value 15 / Tec_ctr fix val 15
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: PERCENT Dyn. index: DDS, p0180
Units group: 9_1 Unit selection: p0595 Func. diagram: 7950
Min Max Factory setting
-200.00 [%] 200.00 [%] 150.00 [%]
p2216[0...n] Technology controller fixed value selection method / Tec_ctr FixVal sel
Access level: 2 Calculated: - Data type: Integer16
Can be changed: T Scaling: - Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 7950, 7951
Min Max Factory setting
1 2 1
p2220[0...n] BI: Technology controller fixed value selection bit 0 / Tec_ctrl sel bit 0
Access level: 3 Calculated: - Data type: U32 / Binary
Can be changed: T Scaling: - Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 7950, 7951
Min Max Factory setting
- - 0