User Manual - Page 241

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
241
2 Parameters
2.2 List of parameters
Description: Displays the ambient temperature for motor temperature model 3.
This value is used to calculate the utilization display (p0034).
The parameter value is an image of p0613.
Dependency: Refer to: r0034
Note: Users cannot see and change parameter p0613 (only Siemens internal).
Description: Displays the alarm threshold for monitoring the motor temperature for motor temperature model 3.
This value is used to calculate the utilization display (p0034).
The parameter value is an image of p5390.
Note: Users cannot see and change parameter p5390 (only Siemens internal).
Description: Sets the fault threshold for monitoring the motor temperature for motor temperature model 3.
Fault F07011 is output after the fault threshold is exceeded.
The parameter value is an image of p5391.
Note: Users cannot see and change parameter p5391 (only Siemens internal).
Description: Displays the PROFIenergy mode ID of the effective energy saving mode.
Value: 0: POWER OFF
2: Energy-saving mode 2
255: Ready
Note: Pe: PROFIenergy profiles
r5397 Mot_temp_mod 3 ambient temperature image p0613 / AmbTmp image p0613
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: -
Units group: 21_1 Unit selection: p0505 Func. diagram: 8017
Min Max Factory setting
- [°C] - [°C] - [°C]
r5398[0...n] Mot_temp_mod 3 alarm threshold image p5390 / A thr image p5390
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Units group: 21_1 Unit selection: p0505 Func. diagram: 8017
Min Max Factory setting
- [°C] - [°C] - [°C]
r5399[0...n] Mot_temp_mod 3 fault threshold image p5391 / F thr image p5391
Access level: 2 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: - Dyn. index: MDS
Units group: 21_1 Unit selection: p0505 Func. diagram: 8017
Min Max Factory setting
- [°C] - [°C] - [°C]
r5600 Pe energy saving mode ID / Pe mode ID
G120C_PN Access level: 3 Calculated: - Data type: Integer16
Can be changed: - Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 255 -