User Manual - Page 245

For G120C.

Loading ...
Loading ...
Loading ...
SINAMICS G120C
List Manual (LH13), 04/2014, A5E33840768B AA
245
2 Parameters
2.2 List of parameters
Note: Parameters with the "WRITE_NO_LOCK" attributes are excluded from the write protection.
A product-specific list of these parameters is also available in the corresponding List Manual.
Description: Sets the behavior for write protection when accessing via multi-master fieldbus systems (e.g. CAN, BACnet).
Value: 0: Write access independent of p7761
1: Write access dependent on p7761
Dependency: Refer to: r7760, p7761
Description: Sets the number of parameters for the OEM exception list (p7764[0...n]).
p7764[0...n], with n = p7763 - 1
Dependency: Refer to: p7764
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: OEM exception list (p7764[0...n] for setting parameters that should be excluded from know-how protection.
p7764[0...n], with n = p7763 - 1
Dependency: The number of indices depends on p7763.
Refer to: p7763
Note: KHP: Know-How Protection
Even if know-how protection is set, parameters in this list can be read and written to.
Description: Configuration settings for know-how protection.
Re bit 00, 01:
When KHP is activated, this means that the OEM can define whether the parameters and DCC data encrypted on the
memory card should be protected before using on other memory cards/Control Units.
Re bit 02:
This means that the OEM can define whether it is possible or not to trace the drive data using the device trace
function although KHP is activated.
p7762 Write protection multi-master fieldbus system access behavior / Fieldbus acc_behav
Access level: 3 Calculated: - Data type: Integer16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 1 0
p7763 KHP OEM exception list number of indices for p7764 / KHP OEM qty p7764
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
1 500 1
p7764[0...n] KHP OEM exception list / KHP OEM excep list
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: p7763
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
0 65535 [0] 7766
[1...499] 0
p7765 KHP configuration / KHP config
Access level: 3 Calculated: - Data type: Unsigned16
Can be changed: U, T Scaling: - Dyn. index: -
Units group: - Unit selection: - Func. diagram: -
Min Max Factory setting
- - 0000 bin
Loading ...
Loading ...
Loading ...