2 Parameters
2.2 List of parameters
SINAMICS G120C
156 List Manual (LH13), 04/2014, A5E33840768B AA
Description: Sets the signal source for the lower torque limit.
Dependency: Refer to: p1520, p1521, p1522
Danger: Positive values resulting from the signal source and scaling can cause the motor to accelerate in an uncontrolled
manner.
Description: Sets the scaling for the upper torque limit.
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: This parameter can be freely interconnected.
Description: Sets the scaling for the lower torque limit.
Notice: A BICO interconnection to a parameter that belongs to a drive data set always acts on the effective data set.
Note: This parameter can be freely interconnected.
Description: Display and connector output for the upper torque limit of all torque limits without offset.
Dependency: Refer to: p1520, p1521, p1522, p1523
Description: Display and connector output for the lower torque limit of all torque limits without offset.
Dependency: Refer to: p1520, p1521, p1522, p1523
p1523[0...n] CI: Torque limit lower / M_max lower
Access level: 3 Calculated: - Data type: U32 / FloatingPoint32
Can be changed: T Scaling: p2003 Dyn. index: CDS, p0170
Units group: - Unit selection: - Func. diagram: 6020, 6630
Min Max Factory setting
- - 1521[0]
p1524[0...n] CO: Torque limit upper scaling / M_max upper scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: PERCENT Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6630
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
p1525[0...n] CO: Torque limit lower scaling / M_max lower scal
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: U, T Scaling: PERCENT Dyn. index: DDS, p0180
Units group: - Unit selection: - Func. diagram: 6630
Min Max Factory setting
-2000.0 [%] 2000.0 [%] 100.0 [%]
r1526 CO: Torque limit upper without offset / M_max up w/o offs
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Units group: 7_1 Unit selection: p0505 Func. diagram: 6060, 6630, 6640
Min Max Factory setting
- [Nm] - [Nm] - [Nm]
r1527 CO: Torque limit lower without offset / M_max low w/o offs
Access level: 3 Calculated: - Data type: FloatingPoint32
Can be changed: - Scaling: p2003 Dyn. index: -
Units group: 7_1 Unit selection: p0505 Func. diagram: 6060, 6630, 6640
Min Max Factory setting
- [Nm] - [Nm] - [Nm]