Loading ...
Loading ...
Loading ...
Trigger
R&S
®
RTB2000
63User Manual 1333.1611.02 ─ 03
First select the standard and the signal polarity, then decide to trigger on lines or fields
and enter the specific settings.
► TRIGGER > "Trigger Type" = "Video"
Figure 5-5: Video trigger menu
Standard........................................................................................................................63
Signal............................................................................................................................ 64
Mode............................................................................................................................. 64
Line............................................................................................................................... 64
Standard
Selects the color television standard.
You can trigger on various standard-definition television (SDTV) signals:
●
"PAL"
●
"NTSC"
●
"SECAM"
●
"PAL-M"
●
"SDTV 576i" (PAL and SECAM)
High-definition television (HDTV) standards are indicated by the number of active lines
and the scanning system:
●
"HDTV 720p"
●
"HDTV 1080p" (p for progressive scanning)
●
"HDTV 1080i" (i for interlaced scanning)
Remote command:
TRIGger:A:TV:STANdard on page 271
Video Trigger
Loading ...
Loading ...
Loading ...