Serial Bus Analysis
R&S
®
RTB2000
183User Manual 1333.1611.02 ─ 03
Remote command:
BUS<b>:I2C:DATA:SOURce on page 384
Threshold, Find Threshold
Set the signal threshold for the source channel. Enter a value, or use "Find Threshold"
to set the threshold to the middle reference level of the measured amplitude.
For analog channels, you can find the value also in the "Vertical" menu > "Chan-
nel <n>" >"Threshold"
For logic channels, you can find the value also in the "Logic" menu > "Threshold".
Remote command:
CHANnel<m>:THReshold on page 256
CHANnel<m>:THReshold:FINDlevel on page 256
DIGital<m>:THReshold on page 433
12.3.3
I
2
C Trigger
Before you set up the trigger, make sure that the bus is configured correctly. See
Chapter 12.3.2, "I
2
C Configuration", on page 182.
To trigger on I
2
C signals:
1. Press the PROTOCOL key in the Analysis area of the front panel.
2. Select the bus that is configured for I2C.
3. Select "Trigger".
This selection has several effects:
Enables decoding, if necessary.
Sets the "Trigger Type" to "Serial Bus" and the trigger source to the selected
bus.
Displays the trigger conditions in the dialog box, below the protocol setup.
4. At "I2C Trigger", select the required trigger type:
"Start": beginning of the message
"Stop": end of the message
"Restart": repeated start condition
"~Acknowledge": transfer of data bits is not acknowledged
"Address and Data": address pattern and/or up to 3 data bytes
5. If "Identifier" or "Identifier and Data" is selected, the CAN trigger setup dialog
expands to define the serial pattern.
6.
If "Address and Data" is selected, the I
2
C trigger setup dialog expands to define the
serial patterns.
I²C (Option R&S RTB-K1)
Loading ...
Loading ...