Remote Control Commands
R&S
®
RTB2000
427User Manual 1333.1611.02 ─ 03
BUS<b>:LIN:FRAMe<n>:BCOunt?
Returns the number of data bytes in the specified frame.
Suffix:
<b>
.
1 | 2
<n> *
Selects the frame (1...n).
Return values:
<ByteCount> Number of words (bytes)
Usage: Query only
BUS<b>:LIN:FRAMe<n>:BYTE<o>:STATe?
Returns the state of the specified data byte.
Suffix:
<b>
.
1 | 2
<n> *
Selects the frame (1...n).
<o> *
Selects the byte number (1...o).
Return values:
<ByteStatus> OK | INS | UART
INS
Insufficient, the byte is not completely contained in the acquisi-
tion.
UART
At least one UART error occured. LIN uses UART words without
parity bit.
Usage: Query only
BUS<b>:LIN:FRAMe<n>:BYTE<o>:VALue?
Returns the decimal value of the specified byte.
Suffix:
<b>
.
1 | 2
<n> *
Selects the frame (1...n).
<o> *
Selects the byte number (1...o).
Return values:
<ByteValue> Decimal value