Remote Control Commands
R&S
®
RTB2000
403User Manual 1333.1611.02 ─ 03
BUS<b>:CAN:DATA:SOURce.........................................................................................403
BUS<b>:CAN:TYPE.......................................................................................................403
BUS<b>:CAN:SAMPlepoint.............................................................................................403
BUS<b>:CAN:BITRate................................................................................................... 404
BUS<b>:CAN:DATA:SOURce <Source>
Sets the source of the data line. All channel waveforms can be used.
Suffix:
<b>
.
1 | 2
Parameters:
<Source> CH1 | CH2 | CH3 | CH4 | D0..D15
Logic channels D0..D15 are available if MSO option R&S RTB-
B1 is installed.
*RST: CH1
BUS<b>:CAN:TYPE <SignalType>
Selects the CAN-High or CAN-Low line. CAN uses both lines for differential signal
transmission.
If you measure with a differential probe, connect the probe to both CAN-H and CAN-L
lines, and set the type CANH.
If you use a single-ended probe, connect the probe to either CAN_L or CAN_H, and
select the type accordingly.
Suffix:
<b>
.
1 | 2
Parameters:
<SignalType> CANH | CANL
*RST: CANH
BUS<b>:CAN:SAMPlepoint <SamplePoint>
Sets the position of the sample point within the bit in percent of the nominal bit time.
See also: "Sample Point" on page 197.
Suffix:
<b>
.
1 | 2
Parameters:
<SamplePoint> Range: 10 to 90
Increment: 1
*RST: 50
Default unit: %
Serial Bus Analysis