Rohde & Schwarz RTB2002 Oscilloscope

User Manual - Page 462

For RTB2002.

PDF File Manual, 510 pages, Read Online | Download pdf file

RTB2002 photo
Loading ...
Loading ...
Loading ...
Remote Control Commands
R&S
®
RTB2000
454User Manual 1333.1611.02 ─ 03
Parameters:
<DutyCycle> Numeric value
Range: 1.00E+00 to 9.900E+01
*RST: 5.000E+01
Default unit: %
Example: PGEN:PATT:SQU:DCYC 20
Sets the duty cycle of the square wave function to 20%.
PGENerator:MANual:STATe<s> <State>
Selects the pins S0 to S3 manually and sets their states to high (H) or low (L).
Suffix:
<s>
.
0..3
Pins S0 to S3
Parameters:
<State> ON | OFF
ON
Pin state is set to high (H).
OFF
Pin state is set to low (L).
*RST: OFF
Example: PGEN:MAN:STAT2 ON
Sets the state of pin S2 to high (H).
15.14 Status Reporting
15.14.1 STATus:OPERation Register
The commands of the STATus:OPERation subsystem control the status reporting
structures of the STATus:OPERation register:
See also:
Chapter C.1, "Structure of a SCPI Status Register", on page 474
Chapter C.3.3, "STATus:OPERation Register", on page 479
The following commands are available:
STATus:OPERation:CONDition?..................................................................................... 455
STATus:OPERation:ENABle........................................................................................... 455
STATus:OPERation:NTRansition.....................................................................................455
STATus:OPERation:PTRansition.....................................................................................455
STATus:OPERation[:EVENt]?......................................................................................... 455
Status Reporting
Loading ...
Loading ...