Rohde & Schwarz RTB2002 Oscilloscope

User Manual - Page 104

For RTB2002.

PDF File Manual, 510 pages, Read Online | Download pdf file

RTB2002 photo
Loading ...
Loading ...
Loading ...
Waveform Analysis
R&S
®
RTB2000
96User Manual 1333.1611.02 ─ 03
"Rising"
Only positive clock edges are considered.
"Falling"
Only negative clock edges are considered.
"Either"
The clock edges next to the data edge are considered regardless of
the clock slope. Use this setting, for example, for signals with double
data rate.
Remote command:
SEARch:TRIGger:DATatoclock:CEDGe on page 291
Setup Time
Sets the minimum time before the clock edge while the data signal must stay steady
above or below the data level.
Remote command:
SEARch:TRIGger:DATatoclock:STIMe on page 291
Hold Time
Sets the minimum time after the clock edge while the data signal must stay steady
above or below the data level.
Remote command:
SEARch:TRIGger:DATatoclock:HTIMe on page 291
6.5.9 Pattern Search
For pattern search, up to four analog channels can be used as source. If MSO option
R&S RTB-B1 is installed, also digital channels can be included in the pattern. For each
channel, you define the state. The states are combined logically, and the time of true
pattern results is compared with a specified time range. Thus you can find state transi-
tions inside or outside this time range.
Select SEARCH > "Search Type" = "Pattern" > "Setup".
Search
Loading ...
Loading ...
Loading ...