Serial Bus Analysis
R&S
®
RTB2000
192User Manual 1333.1611.02 ─ 03
To trigger on UART signals:
1. Press the PROTOCOL key in the Analysis area of the front panel.
2. Select the bus that is configured for UART.
3. Select "Trigger".
This selection has several effects:
Enables decoding, if necessary.
Sets the "Trigger Type" to "Serial Bus" and the trigger source to the selected
bus.
Displays the "UART Trigger" condition in the dialog box, below the protocol
setup.
4. At "UART Trigger", select the required trigger condition:
"Start Bit" or "Frame Start": next start bit or first start bit after idle time
"Frame Start"
"Frame Error"
"Symbol <n>": frame number in a data stream
"Break": a start bit not followed by a stop bit
"Parity Error"
"Pattern": serial pattern of 1, 2, 3 or 4 symbols at a defined position in the data
stream
"Any Symbol": pattern of data bits anywhere in a data stream
5. If "Pattern" or "Any Symbol" is selected, the UART trigger setup dialog expands to
define the serial pattern or the symbol.
UART trigger settings
Figure 12-17: Trigger setup dialog with an example of a UART serial pattern
55 =
Hex value of the 1
st
symbol, with the binary value 01010101
E6 =
Hex value of the 2
nd
symbol, with the binary value 11100110
E (blue) =
Selected nibble in the 2
nd
symbol. The blue color indicates that the keypad is active for this nib-
ble.
8$ =
Hex value of the 3
rd
symbol, where the 1
st
nibble has the binary value 1000 and the 2
nd
nibble is
represented by the "$" character, as it includes one "X" bit (don't care)
AX (gray) =
The 4
th
symbol is not contained in the specified pattern
UART Trigger..............................................................................................................193
Symbol Offset..............................................................................................................193
Numb. of Symb........................................................................................................... 193