Configure System Information
45
Insight Managed 28-Port and 52-Port Gigabit Ethernet Smart Cloud Switches
The allowed range is 1025 to 65535 and the value 123. The default value is 123. When
the default value is configured, the actual client port value used in SNTP packets is
assigned by the operating system.
8. In the Unicast Poll Interval field, specify the number of seconds between unicast poll
requests expressed as a power of 2.
The allowed range is 6 to 10. The default value is 6.
9. In the Broadcast Poll Interval field, specify the number of seconds between broadcast poll
requests expressed as a power of 2.
Broadcasts received prior to the expiry of this interval are discarded. The allowed range is
6 to 10. The default value is 6.
10. In the Unicast Poll Timeout field, specify the number of seconds to wait for an SNTP
response to a unicast poll request.
The allowed range is 1 to 30. The default value is 5.
11. In the Unicast Poll Retry field, specify the number of times to retry a unicast poll request to
an SNTP server after the first time-out before the switch attempts to use the next configured
server.
The allowed range is 0 to 10. The default value is 1.
12. In the Time Zone Name field, specify a time zone.
You can also specify the number of hours and number of minutes that the time zone is
different from the Coordinated Universal Time (UTC). The time zone can affect the
display of the current system time. The default value is UTC.
Note: When using SNTP/NTP time servers to update the switch’s clock, the
time data received from the server is based on the UTC, which is the
same as Greenwich Mean Time (GMT). This might not be the time
zone in which the switch is located.
13. In the Offset Hours field, specify the number of hours that the time zone is different from
UTC.
The allowed range is –12 to 13. The default value is 0.
14. In the Offset Minutes field, specify the number of minutes that the time zone is different
from UTC.
The allowed range is 0 to 59. The default value is 0.
15. Click the Apply button.
Your settings are saved.