18 DETECT MALFUNCTIONING PART
Check the following.
쐌 EVAP canister for damage
쐌 EVAP hose between EVAP canister and water separator for clogging or poor connection
䊳 Repair hose or replace EVAP canister.
19 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR SHIELD CIRCUIT FOR OPEN AND SHORT
1. Reconnect harness connectors disconnected.
2. Disconnect harness connectors C3, B113.
3. Check harness continuity between harness connector B113 terminal 6 and engine ground.
Continuity should exist.
4. Also check harness for short to power.
OK or NG
OK 䊳 GO TO 21.
NG 䊳 GO TO 20.
20 DETECT MALFUNCTIONING PART
Check the following.
쐌 Harness connectors B113 and B101, M67
쐌 Harness connectors M59, F27
쐌 Joint connector-1
쐌 Harness for open between harness connector B113 and engine ground
䊳 Repair open circuit or short to power in harness or connectors.
21 CHECK INTERMITTENT INCIDENT
Refer to “TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT”, EC-732.
䊳 INSPECTION END
DTC P0450 EVAPORATIVE EMISSION (EVAP) CONTROL SYSTEM
PRESSURE SENSOR
VG33E
Diagnostic Procedure (Cont’d)