SEF058Y
DTC Confirmation Procedure
NGEC0260
NOTE:
If “DTC Confirmation Procedure” has been previously conducted,
always turn ignition switch “OFF” and wait at least 5 seconds
before conducting the next test.
TESTING CONDITION:
Before performing the following procedure, confirm battery
voltage is more than 11V at idle.
With CONSULT-II
1) Turn ignition switch ON.
2) Select “DATA MONITOR” mode with CONSULT-II.
3) Start engine and wait at least 5 seconds.
4) If 1st trip DTC is detected, go to “Diagnostic Procedure”,
EC-380.
With GST
Follow the procedure “With CONSULT-II”.
DTC P0446 EVAPORATIVE EMISSION (EVAP) CANISTER
VENT CONTROL VALVE (CIRCUIT)
KA24DE
DTC Confirmation Procedure
EC-378