User Manual - Page 1017

For 2001 XTERRA.

Loading ...
Loading ...
Loading ...
5) Turn ignition switch OFF and wait at least 5 seconds then
turn ON.
6) Select FUEL LEVEL SE in DATA MONITOR mode with
CONSULT-II.
7) Check FUEL LEVEL SE output voltage and note it.
8) Select FUEL PUMP in ACTIVE TEST mode with CON-
SULT-II.
9) Touch ON and drain fuel approximately 30 (7-7/8 US gal,
6-5/8 Imp gal) and stop it.
10) Fill fuel into the fuel tank for 30 (7-7/8 US gal, 6-5/8 Imp gal).
11) Check FUEL LEVEL SE output voltage and note it.
12) Check FUEL LEVEL SE output voltage and confirm whether
the voltage changes more than 0.03V during step 7 to 11.
If NG, check the fuel level sensor, refer to EL-87, FUELLEVEL
SENSOR UNIT CHECK.
SEF802Z
WITH GST
NGEC0978S02
NOTE:
Start from step 11, if it is possible to confirm that the fuel
cannot be drained by 30 (7-7/8 US gal, 6-5/8 Imp gal) in
advance.
1) Prepare a fuel container and a spare hose.
2) Release fuel pressure from fuel line, refer to Fuel Pressure
Release, EC-637.
3) Remove the fuel feed hose on the fuel level sensor unit.
4) Connect a spare fuel hose where the fuel feed hose was
removed.
5) Turn ignition switch OFF.
6) Set voltmeters probe between ECM terminal 46 (fuel level
sensor signal) and ground.
7) Turn ignition switch ON.
8) Check voltage between ECM terminal 46 and ground and note
it.
9) Drain fuel by 30 (7-7/8 US gal, 6-5/8 Imp gal) from the fuel
tank using proper equipment.
10) Fill fuel into the fuel tank for 30 (7-7/8 US gal, 6-5/8 Imp gal).
11) Confirm that the voltage between ECM terminal 46 and ground
changes more than 0.03V during step8-10.
If NG, check component of fuel level sensor, refer to EL-87,
FUEL LEVEL SENSOR UNIT CHECK.
DTC P0461 FUEL LEVEL SENSOR FUNCTION
VG33E
Overall Function Check (Contd)
EC-1017
GI
MA
EM
LC
FE
CL
MT
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
EL
IDX
Loading ...
Loading ...
Loading ...