ECM Terminals and Reference Value
=NGEC0921
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than the ECM terminals, such as the ground.
TERMI-
NAL
NO.
WIRE
COLOR
ITEM CONDITION DATA (DC Voltage)
11 W/R Fuel pump relay
[Ignition switch ON]
For 5 seconds after turning ignition switch ON
[Engine is running]
0-1V
[Ignition switch ON]
More than 5 seconds after turning ignition switch
ON
BATTERY VOLTAGE
(11 - 14V)
FUEL PUMP
VG33E
ECM Terminals and Reference Value