SEF237U
On Board Diagnosis Logic
NGEC0097
Under the condition in which the heated oxygen sensor 1 (front)
signal is not input, the ECM circuits will read a continuous approxi-
mately 0.3V. Therefore, for this diagnosis, the time that output
voltage is within 200 to 400 mV range is monitored, and the diag-
nosis checks that this time is not inordinately long.
DTC No. Malfunction is detected when ... Check Items (Possible Cause)
P0130 쐌 The voltage from the sensor is constantly approx. 0.3V. 쐌 Harness or connectors
(The sensor circuit is open or shorted.)
쐌 Heated oxygen sensor 1 (front)
DTC P0130 HEATED OXYGEN SENSOR 1 (FRONT) (CIRCUIT)
KA24DE