9 CHECK HO2S2 (REAR) SHIELD CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect joint connector-3.
3. Check the following.
Continuity between joint connector terminal 1 and ground
Joint connector
(Refer to EL-244, HARNESS LAYOUT.)
Continuity should exist.
4. Also check harness for short to power.
5. Then reconnect joint connector-3.
OK or NG
OK GO TO 10.
NG Repair open circuit or short to power in harness or connectors.
10 CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT, EC-732.
INSPECTION END
DTC P0137, P0157 HEATED OXYGEN SENSOR 2 (REAR)
(BANK 1)/(BANK 2) (MIN. VOLTAGE MONITORING)
VG33E