CONSULT-II Reference Value in Data Monitor
Mode
NGEC0441
Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
START SIGNAL Ignition switch: ON , START , ON OFF , ON , OFF
ECM Terminals and Reference Value
NGEC0442
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than ECM terminals, such as the ground.
TERMI-
NAL
NO.
WIRE
COLOR
ITEM CONDITION DATA (DC Voltage)
20 L/OR Start signal
[Ignition switch ON] Approximately 0V
[Ignition switch START]
BATTERY VOLTAGE
(11 - 14V)
START SIGNAL
KA24DE