9 CHECK HO2S2 (REAR) SHIELD CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Disconnect joint connector.
3. Check the following.
Continuity between joint connector terminal 1 and ground
Joint connector
(Refer to HARNESS LAYOUT, EL-9.)
Continuity should exist.
4. Also check harness for short to power.
5. Then reconnect joint connector.
OK or NG
OK GO TO 10.
NG Repair open circuit or short to power in harness or connectors.
10 CHECK INTERMITTENT INCIDENT
Refer to TROUBLE DIAGNOSIS FOR INTERMITTENT INCIDENT, EC-732.
INSPECTION END
DTC P0138, P0158 HEATED OXYGEN SENSOR 2 (REAR)
(BANK 1)/(BANK 2) (MAX. VOLTAGE MONITORING)
VG33E
Diagnostic Procedure (Contd)
EC-855