SEF032W
SEF143S
Component Description
NGEC0852
The EVAP canister vent control valve is located on the EVAP can-
ister and is used to seal the canister vent.
This solenoid valve responds to signals from the ECM. When the
ECM sends an ON signal, the coil in the solenoid valve is ener-
gized. A plunger will then move to seal the canister vent. The abil-
ity to seal the vent is necessary for the on board diagnosis of other
evaporative emission control system components.
This solenoid valve is used only for diagnosis, and usually remains
opened.
When the vent is closed, under normal purge conditions, the
evaporative emission control system is depressurized and allows
EVAP Control System (Small Leak) diagnosis.
CONSULT-II Reference Value in Data Monitor
Mode
NGEC0853
Specification data are reference values.
MONITOR ITEM CONDITION SPECIFICATION
VENT CONT/V Ignition switch: ON OFF
ECM Terminals and Reference Value
NGEC0854
Specification data are reference values and are measured between each terminal and ground.
CAUTION:
Do not use ECM ground terminals when measuring input/output voltage. Doing so may result in dam-
age to the ECMs transistor. Use a ground other than the ECM terminals, such as the ground.
TERMI-
NAL
NO.
WIRE
COLOR
ITEM CONDITION DATA (DC Voltage)
108 R/G
EVAP canister vent control
valve
[Ignition switch ON]
BATTERY VOLTAGE
(11 - 14V)
DTC P1446 EVAPORATIVE EMISSION (EVAP) CANISTER VENT
CONTROL VALVE (CLOSE)