6 CHECK THERMOSTAT
1. Check valve seating condition at normal room temperatures.
It should seat tightly.
2. Check valve opening temperature and valve lift.
SLC343
Valve opening temperature:
82°C (180°F) [standard]
Valve lift:
More than 10 mm/95°C (0.39 in/203°F)
3. Check if valve is closed at 5°C(9°F) below valve opening temperature.
For details, refer to Thermostat, LC-29.
OK or NG
OK GO TO 7.
NG Replace thermostat
DTC P1217 ENGINE OVERTEMPERATURE (OVERHEAT)
(WITH ELECTRIC COOLING FAN)
VG33E
Diagnostic Procedure (Contd)
EC-1057