User Manual - Page 1090

For 2001 XTERRA.

Loading ...
Loading ...
Loading ...
20 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
Never apply force to the air hole protector of the sensor if equipped.
SEF799W
2. Remove hose from EVAP control system pressure sensor.
3. Turn ignition switch ON.
4. Use pump to apply vacuum and pressure to EVAP control system pressure sensor as shown in figure.
CAUTION:
Always calibrate the vacuum pump gauge when using it.
Do not apply below 20 kPa (150 mmHg, 5.91 inHg) or over 20 kPa (150 mmHg, 5.91 inHg) of pressure.
5. Check input voltage between ECM terminal 84 and ground.
SEF342X
CAUTION:
Discard and EVAP control system pressure sensor which has been dropped from a height of more than 0.5m
(19.7in) onto a hard surface such as a concrete floor; use a new one.
OK or NG
OK GO TO 21.
NG Replace EVAP control system pressure sensor.
21 CHECK EVAP PURGE LINE
Check EVAP purge line (pipe, rubber tube, fuel tank and EVAP canister) for cracks or improper connection.
Refer to Evaporative Emission System, EC-619.
OK or NG
OK GO TO 22.
NG Repair or reconnect the hose.
22 CLEAN EVAP PURGE LINE
Clean EVAP purge line (pipe and rubber tube) using air blower.
GO TO 23.
DTC P1441 EVAP CONTROL SYSTEM (VERY SMALL LEAK)
VG33E
Diagnostic Procedure (Contd)
EC-1090