8 CHECK FUEL PUMP RELAY
With CONSULT-II
1. Reconnect fuel pump relay, fuel pump harness connector and ECM harness connector.
2. Turn ignition switch ON.
3. Turn fuel pump relay “ON” and “OFF” in “ACTIVE TEST” mode with CONSULT-II and check operating sound.
SEF073Y
Without CONSULT-II
Check continuity between terminals 3 and 5.
SEF511P
12V direct current supply between terminals 1 and 2
Continuity exists
No current supply
Continuity does not exist
OK or NG
OK 䊳 GO TO 9.
NG 䊳 Replace fuel pump relay.
FUEL PUMP
VG33E
Diagnostic Procedure (Cont’d)