External Port
The port of the external control board (the device).
Protocol
Select the network transmission protocol according to the actual needs. TCP ensures
complete delivery of streaming data and beer video quality, but the real-me transmission
will be aected. UDP provides real-me audio and video streams.
4.
Slide to enable the added address mapping.
5.
Oponal: The other operaons.
Edit address
mapping
Click to edit the address mapping informaon.
Delete address
mapping
Click to delete the single address mapping. Or check the address
mappings to be deleted, and click Delete to delete them.
3.2 Data Connecon
3.2.1 Connect to ISUP Plaorm
ISUP is a plaorm access protocol. The device can be remotely accessed via this plaorm.
Before You Start
●
Create the device ID on ISUP
plaorm.
●
Ensure the device can communicate with the plaorm normally.
Steps
1.
Select the radar and click in the client soware, or enter the IP address of the radar in the
address bar of the web browser. Go to
Conguraon → Network → Data Connecon → ISUP .
2.
Check Enable ISUP.
Figure 3-4 Connect to ISUP Plaorm
Security Radar User Manual