than the specified lower limit of pulse width and smaller than the specified
upper limit of pulse width.
Pulse Width Setting:
• When">" or "<" is set to trigger conditions, press Lower or Upper , and then
rotate the multifunction knob to set the lower limit value or the upper limit
value. You can also use the pop-up numeric keypad to set it. The pulse range
available is from 800 ps to 10 s.
•
When the trigger condition is set to "<>", press
Upper and Lower, and then
rotate the multifunction knob to set the upper limit value and the lower limit
value. You can also use the pop-up numeric keypad to set them.
NOTE
The lower limit of the pulse width must be smaller than the upper limit.
Trigger Mode:
In the trigger control area (Trigger) on the front panel, press to quickly switch
the current trigger mode. For details, refer to descriptions in "
Trigger Mode
".
Trigger Parameter Setting:
Sets the trigger parameters (trigger holdoff and noise rejection) under this trigger
type. For details, refer to descriptions in "
Trigger Holdoff
" and "
Noise Rejection
".
Trigger LEVEL/Threshold Level:
Rotate the Trigger LEVEL knob to adjust the trigger level or threshold level. Please
refer to descriptions in "
Trigger LEVEL/Threshold Level
". The current trigger level/
threshold level is displayed at the upper-right corner of the screen.
8.7.3 Slope Trigger
In Slope trigger, the oscilloscope triggers on the positive or negative slope of the
specified time. This trigger mode is applicable to ramp and triangle waveforms.
In this oscilloscope, positive slope time is defined as the time difference between the
two crossing points of trigger level line A and B with the rising edge; negative slope
time is defined as the time difference between the two crossing points of trigger level
line A and B with the falling edge. As shown in the figure below:
To Trigger the Oscilloscope
Copyright ©RIGOL TECHNOLOGIES CO., LTD. All rights reserved.