DGS-1520 Series Gigabit Ethernet Smart Managed Switch Web UI Reference Guide
90
Parameter Description
NTP Max Associations
Enter the NTP maximum association value here. This is used to configure the
maximum number of NTP peers and clients on the Switch. The range is from 1 to
64.
Click the Apply button to accept the changes made.
NTP Server Settings
This window is used to display and configure the NTP server settings. This is used to enable the Switch to
synchronize time with an NTP server.
To view the following window, click Management > NTP > NTP Server Settings, as shown below:
Figure 4-72 NTP Server Settings Window
The fields that can be configured are described below:
Parameter Description
IP Address
Select and enter the IPv4 address of the NTP server here.
IPv6 Address
Select and enter the IPv6 address of the NTP server here.
Version
Enter the NTP version number here. The range is from 1 to 4.
Key ID
Enter the authentication key ID here. The range is from 1 to 255.
Min Poll
Enter the minimum poll value here. This specifies the minimum poll interval for
NTP messages. This value is calculated as 2 to the power of the minimum poll
interval value specified. For example, if the value specified here is 6, the minimum
poll interval that will be used is 64 seconds (2
6
=64). The range is from 3 to 16.
Max Poll
Enter the maximum poll value here. This specifies the maximum poll interval for
NTP messages. This value is calculated as 2 to the power of the maximum poll
interval value specified. For example, if the value specified here is 6, the maximum
poll interval that will be used is 64 seconds (2
6
=64). The range is from 4 to 17.
Prefer
Select whether or not this entry will be the preferred server for synchronization.
Options to choose from are True and False.
Click the Apply button to accept the changes made.
Click the Edit button to re-configure the specific entry.
Click the Delete button to delete the specified entry.