Epson SLD1070DE SureLab D1070DE Professional Minilab Printer with Duplex Sheet Feeder

User Manual - Page 104

For SLD1070DE.

PDF File Manual, 198 pages, Read Online | Download pdf file

SLD1070DE photo
Loading ...
Loading ...
Loading ...
SL-D1000 Series User's Guide
Using the Maintenance Tool (Mac)
104
2
Select Normal or Saving Ink, and then click
Execute.
Nozzle check is executed.
3
Check the results of the nozzle check in the
message displayed on screen.
When “No clogged nozzles were detected.” is
displayed, the work is complete.
When “Clogged nozzles were found.” is
displayed, execute Diagnostic Cleaning.
U
“Diagnostic Cleaning” on page 105
Perform Print Check Pattern to check the
condition of the nozzles.
U
“Print Nozzle Check Pattern Method” on
page 104
Print Nozzle Check Pattern
Method
1
Load paper to print a nozzle check pattern.
U
“Basic Operations” on page 29
2
In the control panel screen, select Printer Setup
- Paper Source Settings - Paper path for
maintenance printing, in this order, and then
set the paper source for the paper loaded in step
1.
3
Click Nozzle Check on the main screen.
The Nozzle Check screen is displayed.
4
Select Print Nozzle Check Pattern, and then
click Execute.
The check pattern is printed.
5
Review the printed check pattern while referring
to the following section.
Example of clean nozzles
If none of the check pattern is missing, then the
print head nozzles are not clogged.
Example of clogged nozzles
If part of the pattern is missing, then the print
head nozzles are clogged. The print head needs
to be cleaned.
U
“Print Head Cleaning Method” on page 105