No. Single-Door Access Controller
C11 Access Controller
RS485 Interface
RS485C+ Uplink
RS485+Communicaon
C12 RS485C- Uplink RS485-
Communicaon
C13 GND Grounding
C14 RS 485D+ Reserved
C15 RS 485D-
C16 GND
C17 Alarm Output NO/NC1 Alarm Relay 1 Output
(Dry Contact)
C18 COM1
C19 NO/NC2 Alarm Relay 2 Output
(Dry Contact)
C20 COM2
D1 Event Input C2 Event Alarm Input 2
D2 GND Grounding
D3 C1 Event Alarm Input 1
Note
●
The Alarm input hardware interface is normally open by default. Only the normally open signal is
allowed. It can be linked to the buzzer of the card reader and access controller, the alarm relay
output, and door relay open and close.
●
Arming region alarm input linkage is only for the alarm relay output linkage.
●
RS-485 card reader ID should be set as 1to 2. The table displayed below shows the relaonship
between the door No. and the ID.
Door No. RS-485 Card Reader ID Descripon
Door 1 1 Enter
2 Exit
●
For single-door access controller, the Wiegand card reader and door's relaonship is as follows.
Access Controller User Manual
11