Loading ...
Loading ...
Loading ...
Control Door Status
You can control the status for a single access control point (door), including opening door, closing
door, remaining open, and remaining closed.
Perform this task when you need to control the door's status.
Steps
1.
Click Status Monitor → Door Status to door status monitoring page.
2.
Select an access control group on the le.
Note
For managing the access control group, refer to Group Access Control Points..
The access control points of the selected access control group will be displayed on the right.
3.
Click on the Status Informaon panel to select a door.
4.
Click the following buons listed on the Status Informaon panel to control the door.
Open Door
Open the door once.
Close Door
Close the door once.
Remain Open
Keep the door open.
Remain Closed
Keep the door closed.
Note
●
Make sure the door has linked to a door contact, or the door status cannot be displayed in the
operaon log.
●
Make sure the access control point cannot be armed by other client soware, or you may not
view the changes of door status. Only one client soware can arm the device, and then view
the changes of the door status, receive the alarm messages from the access control point.
Check Real-me Access Records
The access records of all access control devices will display in real me, including card swiping
records, face recognions records, ngerprint comparison records, etc.
Steps
1.
Click Status Monitor and you can view the real-me access records.
The logs of access records will display in real me. You can view the details of the records,
including card No., person name, organizaon, event me, etc.