Below is an example of testing the power-up stresses on a MOSFET and judging if the stresses are
safe for the MOSFET using the SOA:
Voltage and current waveforms on the MOSFET at power-up
SOA, in which the mask is created according to the voltage limit, current limit, and power
limit. The result shows “Pass” because all the stresses are within the mask.