14.8 CAN FD Trigger and Serial Decode
This section covers triggering and decoding CAN FD signals. Please read the following for more details:
"CAN FD Signal Settings", "CAN FD Trigger" and "CAN FD Serial Decode".
14.8.1 CAN FD Signal Settings
Connect the CAN FD signal to the oscilloscope, and then set the threshold level of the signal. The
process of specifying the source and threshold is similar to "I2C Signal Settings".
In BusConfig menu of trigger and decode, the nominal baud rate can be set to: 10 kb/s, 25 kb/s, 50
kb/s, 100 kb/s, 250 kb/s, 1 Mb/s or Custom. The data baud rate can be set to: 500 kb/s, 1 Mb/s, 2 Mb/s,
5 Mb/s, 8 Mb/s, 10 Mb/s or Custom.
The method of copying settings is the same as I2C signal settings. See "I2C Signal Settings" for details.
14.8.2 CAN FD Trigger
Click Trigger Setting in the CAN FD trigger dialog box to set the trigger conditions:
A. Frame Type: Both, CAN, CAN FD
B. When the "Frame Type" is CAN FD,
turn on or off ISO
C. When the "Frame Type" is CAN FD,
set the BRS (Bit Rate Switch) to Both,
Normal or FD
D. Trigger Condition: Start, Remote, ID,
ID + Data, Error
E. Return to the previous menu