82
3. Select a desired camera under Choose Camera and select Enable Setting to define the counter.
Define Detection Zones: Select this option to define the detection zones.
a. On the live view, draw at least two boxes to mark the in and out detection zones.
Each detection zone is numbered. Use these buttons to edit the detection zones:
Name Button Function
Reverse
Flips the detection zone.
Switch
Switches to another detection zone.
Delete
Deletes the detection zone.
Direction
Configures the in and out directions. See Step 3-b.
b. Click the
button to define the in and out criteria. This dialog box appears.
Figure 3-2
c. Select In/Out under Set Direction and define the direction in Select Detection Zone.
d. Click Add. The setting is added and appears in the table below.
e. Click OK. The directions are added and indicated by arrows on the live view.
Define Object Size: Select this option and click
to pause the live view.
Outline a size matching that of targeted objects on the live view. Click
to resume.
4. To test your counting settings, select Live from the Test Count drop-down list and click the Test
button to start testing. The number in Counting Result should change as objects move through
the detection zone. Optionally use the Sensitivity slider to adjust detection sensitivity as needed.
5. Click OK to apply the settings.
6. Start monitoring to begin counting. The counted objects, people or animals are indicated on the
live view with yellow boxes.